How does catalase concentration affect the rate of the reaction with hydrogen peroxide?

I am experienced in the fields of biology, physics and chemistry, and I enjoy writing on these topics.

Introduction

Catalase is an enzyme which is found in most living organisms. It catalyses the decomposition of hydrogen peroxide into water and oxygen.

2H2O2 + Catalase >>> 2H2O + O2

Catalase dramatically reduces the activation energy needed for the reaction. Without catalase, the decomposition would take much longer and would not be fast enough to sustain human life. Hydrogen peroxide is also a dangerous, very potent by-product of metabolism, and it is essential that it is broken down quickly so it does not cause damage to cells.

Aim

Investigate the effect of substrate concentration on the rate of activity of the enzyme catalase.

Hypothesis

I believe that as the concentration of the hydrogen peroxide (substrate) decreases, the rate of reaction will decrease as well. This is because as there are progressively fewer molecules of hydrogen peroxide there will be fewer collisions between the substrate and enzyme molecules (catalase in yeast), leading to a decrease in enzyme-substrate complexes formed. Because the enzyme is the limiting factor, the reaction will stop completely when all of the active sites become saturated with substrate. This will result in a decreased volume of oxygen being produced as one of the by-products of this reaction.

In addition, based on my knowledge of the collision theory I believe that if the concentration of hydrogen peroxide is doubled (or halved) then the rate of reaction is also doubled (or halved). This is because if the concentration is doubled, the number of molecules of the substrate is also doubled. This means there will be twice as many successful collisions. Therefore it is true to say that in theory, rate µ concentration.

I will investigate if this is true for this reaction.

Preliminary Work

As a result of my preliminary work, I have identified problems that may occur in my main investigation, such as timing, measuring, and keeping variables that I am not investigating constant. Here are the proposed solutions to the problems I identified.

Control Temperature With a Water Bath

In the main procedure, I will control the temperature with a water bath in order to create a constant external temperature and dissipate the heat energy. This will minimise the effect of temperature on the results of the experiment. I have decided to do this because during my preliminary procedures I used a thermometer to measure the temperature of the hydrogen peroxide (when left on the side) at different intervals and on different days, and I found that the temperature of the hydrogen peroxide fluctuated slightly.

By doing this, it will ensure that the test is as fair as I can make it. Although the reaction is exothermic and will give out heat during the reaction anyway, dissipating the heat with the water bath means the amount of heat given off in the experiment will be relative to the concentration of hydrogen peroxide. Obviously, some reactions will take longer than others, so more heat will be produced, however, the initial temperature will be kept the same in each case.

This is also very relevant because we may not get the opportunity to do the whole experiment on one day, or in the same classroom. This means the room temperature in each classroom or on different days will not be the same for each procedure, because of obvious factors such as the type of day (very cold or mild, etc.) and the level of heating within the classrooms.

Temperature directly affects the shape of the active site. At a temperature below the optimum, the molecules have less kinetic energy, so the rate of collisions between enzyme and substrate molecules is low, therefore less enzyme-substrate complexes are formed. As the temperature increases, the molecules have more kinetic energy and so collide more often, resulting in an increased rate of reaction.

Because of this, it is very important to ensure a constant temperature is maintained. Above the optimum temperature, the thermal energy breaks the hydrogen bonds holding the secondary and tertiary structure together, so the active site changes shape and eventually the reaction can no longer be catalysed.

I will keep the water bath at 25°C because the optimum temperature for the enzyme catalase is 45°C. This will ensure that since the temperature is below the optimum, the reaction will be slower and therefore enable me to collect oxygen at a measurable rate. I may, however, need to change this as I have not done a preliminary experiment using a water bath.

Scroll to Continue

Read More From Owlcation

Reduce Mass of Yeast

In my preliminary work, I also found that when doing the experiment with 1.0g of yeast and 5cm3 of 20 volume of hydrogen peroxide, the rate of reaction was too fast to collect oxygen at a measurable rate, and therefore made it impossible to gain meaningful results. I consequently reduced the mass of yeast to 0.2g rather than the 1.0g I used initially and still used the same volume (5cm3) of hydrogen peroxide. This meant that because the enzyme concentration (catalase in yeast) was reduced, there were fewer collisions between enzyme and substrate molecules, so the rate of enzyme-substrate formations was reduced. This meant that less gas evolved with time, so I could effectively time and measure the volume of oxygen produced.

Ensure Consistent Surface Area of Yeast Granules

Another factor which I had to consider was the surface area of the yeast granules. Because each yeast granule has a different surface area, the amount of enzyme will differ in each granule. More importantly, the greater the surface area of the yeast, the more reactions take place because there will be more collisions between the enzyme and substrate molecules.

In my first preliminary experiment, I weighed 1.0g of yeast as it was supplied in its granule form. However, in my next preliminary experiment, I decided this would be unfair in the main procedure. Because of this, I decided to grind the yeast into a powder so that the surface area would be more similar in each yeast granule.

Also, in my main procedure, I will grind a larger mass of yeast (more than I need), and then weigh it, rather than weighing the yeast and then grinding it. This is important because if I weigh the yeast and then grind it with the pestle, some of the yeast will be lost because it might get stuck to the pestle, hence slightly decreasing the mass of yeast. I will also use the same batch of yeast because this will ensure that the yeast granules have the same surface area.

Use Small Decreases in Hydrogen Peroxide Concentration

I will use the following concentrations of hydrogen peroxide: 100%, 90%, 80%, 70%, 60% and 50%. I will use these concentrations because I believe that if I were to go any lower than 50%, the rate of reaction would be relatively slow, and would not produce enough results because the substrate concentration (hydrogen peroxide) would be too low. I also want to decrease in 10% increments because I believe it will provide me with closer results rather than decreasing by 20%, which would mean testing a concentration of 0% of hydrogen peroxide. Finally, I also want to determine whether or not half the 100% concentration of hydrogen peroxide (50%) will produce half the volume of gas.

Choose Optimal Method

I also used two different methods in order to determine which would be the most effective in gaining the best possible results with minimal error.

1) In my first experiment, I used the displacement of water method, whereby a measuring cylinder (containing water) is placed upside down in a plastic tub with a tube attached to the test tube (airtight). A syringe with hydrogen peroxide is also present (as shown Fig. 1, below). The hydrogen peroxide is injected into the test tube, and the volume of oxygen gas is recorded (by the amount of water displaced), determining the rate of reaction. However, I decided against this method for several reasons. Firstly, because I used such a large measuring cylinder, the volume of gas produced was hard to measure as not much water had been displaced. Although I could have used a smaller measuring cylinder, I decided that the best possible way I could do the experiment was by measuring the volume of gas directly using a gas syringe, rather than by the displacement of water. Also, because the hydrogen peroxide had to be inserted into the syringe before the reaction could begin, the amount of time it would be out of the water bath (which I intend to use in my main experiment) was longer than necessary. I decided that I could reduce this time by using a different method.

Figure 1: experiment diagram

Figure 1: experiment diagram

2) In my second preliminary experiment, I used a gas syringe instead, which measured the volume of oxygen produced directly, rather than by the displacement of water. The hydrogen peroxide is inserted into a 5cm3 beaker and then tipped over to 'spill' the contents and start the reaction. I felt that this would give me more reliable results in my main investigation because the length of time that the hydrogen peroxide is out of the water bath is reduced.

Furthermore, the volume of gas is measured directly. I noticed that when doing the first method that 'bubbles of gas' were affected by people bumping the table, and that sometimes they got trapped in the tube, so even though the product of the reaction (oxygen) had been formed, it was not measured until afterwards (at a later stage in the reaction). Also, the bubble volume is affected by the diameter of the tube and the overall pressure of the water (depth) so I believe that by using the gas syringe, I will be able to eliminate this inaccuracy as water will not be involved. The gas syringe, however, has a small volume of air displaced within it when it is attached to the conical flask, so I will have to consider this in the main procedure. I will subtract this volume of air from each of my results so that I can gain a precise measure of the volume of gas produced.

My preliminary experiments also gave me an idea as to how often I should measure the volume of gas formed (i.e. every 5, 10, 15 seconds etc). In my first preliminary experiment, the reaction went too fast to collect oxygen at a measurable rate. In the second preliminary experiment, I measured the volume of gas every 10 seconds but found that the reaction was over before I had enough measurements and that the results I gained would not be sufficient to obtain enough data to make a valid conclusion.

Therefore I did a further experiment based on timing only and found that if I measured the volume of gas every 5 seconds I obtained enough measurements.However, I do have to take into account that I will be using different concentrations of hydrogen peroxide in my main experiment, so 5 seconds may not be sufficient to measure the volume of oxygen produced in the slower reactions, and I may need to change this.

Independent Variable

The independent variable (the factor that I manipulate) will be the concentration of the hydrogen peroxide. I intend to use a pipette in order to make the concentrations of 100%, 90%, 80%, 70%, 60%, and 50%. I will do this by making each mixture up to 100cm3, so for example, the 90% concentrated solution will consist of 90cm3 of hydrogen peroxide and 10cm3 water. I will put the 6 different concentrated solutions in a conical flask which will be placed in a water bath.

Because a pipette is a very accurate way of measuring volumes, I believe that this will be the best method to make the concentrations. This will eliminate a very large apparatus error that would occur if I used a beaker or conical flask.

Dependent Variable

The dependent variable (the one I intend to measure) is the volume of gas produced in each reaction. This will vary as a direct result of the different concentrations of hydrogen peroxide.

Controlled Variables

The controlled variables are the other factors which must be kept constant.

One such variable will be the mass of yeast for each experiment (0.2g). I will make sure that I measure 0.2g of yeast as accurately as I can using the balance. The balance has a mechanism whereby it can be made level (perfectly balanced) regardless of the angle of the desk or counter it is placed on. I have explained this in my method below. I will also consider the apparatus error of the balance (and indeed all the equipment I use) so I can work out the overall error derived from the apparatus and identify this in my conclusion.

I am also controlling the temperature. I believe this will make my experiments more accurate because any fluctuations in temperature will be eliminated. It will also rule out the fact that if I have to do my procedures in different rooms and on different days, the temperature in the room might change.

Apparatus

  • Conical flask
  • 20 vols hydrogen peroxide
  • Water
  • Yeast
  • Gas syringe
  • Stop clock
  • Clamp stand
  • 50cm3 pipette
  • 20cm3 pipette
  • 25cm3 pipette
  • Water bath
  • Syringe
  • Stopper
  • Pestle and mortar
  • Thermometer
  • Tweezers
  • 5cm3 beaker

Method

  1. Measure out the concentrations of hydrogen peroxide (100%, 90%, 80%, 70%, 60% and 50%) by adding different volumes of water to make up 100cm3. For example, the 80% concentrated solution will consist of 80cm3 of hydrogen peroxide and 20cm3 of water (as shown in Fig. 2 below). Note: Use a pipette rather than a conical flask or a measuring cylinder because pipettes are very accurate for measuring volumes.
  2. Place the six conical flasks in a water bath at 25oC to create a constant external temperature and dissipate heat energy. Do this first to ensure that the mixtures have enough time to reach a constant temperature instead of putting them in for a short time.
  3. Grind the yeast into a powder using a pestle and mortar. Note: Grind up more than required, so you can use the same (ground) yeast for each experiment. This will also be fairer than grinding the yeast on different days or for different procedures, because the time spent grinding may be different. Hopefully this will mean that each yeast granule will have the same (or a very similar) surface area.
  4. Set up your apparatus.
  5. Place the balance on the table, making sure the bubble in the spirit level is in the middle. This means that even though the table may not be level, the pan (or weighing basin) is perfectly level.
  6. Place a conical flask on the balance, and set the balance to 0, so that you can weigh the yeast only.
  7. Place yeast in the conical flask using a spatula until you have reached the right weight (0.2g). Weigh the yeast directly into the conical flask, not a Petri dish, so you do not have to worry about losing yeast mass when transferring it from the Petri dish to the conical flask.
  8. Place the conical flask under the gas syringe and place an airtight stopper in the top, with a single tube attached to the gas syringe (as shown in Fig. 1).
  9. Take the conical flask with the 100% hydrogen peroxide out of the water bath and measure exactly 5cm3 of the mixture using a syringe.
  10. Place it in the 5cm3 small beaker. Being very careful as not to spill the mixture, take the stopper off the conical flask and lower the beaker into the conical flask using tweezers.
  11. Put the stopper back in the conical flask so the procedure can begin.
  12. Use a stop clock to time from the moment the small beaker is tipped over to when the reaction stops, measuring the volume of gas evolved every 15 seconds. The reaction is over when you have recorded three volumes of gas that are concordant or very similar. This indicates that no more gas is being produced because the enzyme is the limiting factor (reaction plateaus when all active sites are occupied).
  13. Repeat steps 6-12 using the different concentrations of hydrogen peroxide and making sure to wash the equipment thoroughly after each reaction.
  14. Carry out each reaction three times to gain an average. Hopefully, you will record concordant results for each repeat, so if an anomaly occurs you can discount it and repeat the procedure again.
  15. Record the data in a table (see Fig. 3) and use it to work out the rate of reaction.
  16. Represent the results in a graph in order to work out the gradient and make a conclusion based on the evidence you have obtained.

Figure 2: composition of hydrogen peroxide concentrations

Figure 2: composition of hydrogen peroxide concentrations

Safety

Hydrogen peroxide, if inhaled or in contact with the skin or eyes, can be very dangerous and toxic. For this reason, I will take the following safety precautions:

  • Wear safety goggles and gloves whenever handling the hydrogen peroxide.
  • Keep hair tied back at all times.
  • Do not wear any jewellery or articles of clothing that may come into contact with the hydrogen peroxide.
  • Clean up any spillages immediately.

Graphs

Predict what the graph will show.

I believe that the graph will start off steep in all the reactions, but steepest in the 100% concentration of hydrogen peroxide and gradually decrease as the concentration of hydrogen peroxide decreases. This is because there will be more collisions between the enzyme and substrate molecules resulting in more enzyme-substrate complexes.

The curve will then level off, representing the point where most of the enzymes' active sites are saturated. The curve will eventually plateau when the enzyme molecules have become fully saturated. This is called the maximum velocity of the reaction or Vmax. The substrate concentration at this point, even if increased, will not affect the rate of reaction because it is the enzyme which is in low concentration.

Draw a graph showing what your PREDICTION will be, and write a statement (such as the one below) showing why the graph shows what it does.

I believe that each curve for each concentration will follow the pattern I described above, but for each decreased concentration—90%, 80%, 70%, 60% and 50%—the value of the Vmax will decrease too, as will the initial rate of reaction. This is because there will be fewer substrate molecules in each successive concentration, so fewer collisions between particles that can react with each other. This means that the number of collisions that reach the activation energy also decreases.

This can be explained by the Maxwell-Boltzmann distribution curve.

Then draw the graph using your results or the ones in the table below (Fig. 5).

Recording Results

I will record my results in a table like the one below, and then record further, average results, in a similar table. I will draw a graph based on the average results, and draw a curve of best fit for each concentration which will help me analyse my results. I will then work out the gradient of each curve and plot a further graph of percentage of H2O2 against the rate of reaction on the y-axis. I would expect this graph to be linear as this would show that as the concentration increases, the time taken for a set volume of gas would decrease. In other words, the rate is proportional to the concentration. I expect this graph to look similar to the ones I have described above. I will work out the rate of reaction from the results gained in the first 5 seconds as this will be the point where the greatest volume of gas evolves.

Figure 3: blank table to fill in

Figure 3: blank table to fill in

Implementing

I had to change the volume of hydrogen peroxide used from 5cm3 to 4cm3 because the first reaction with 100% hydrogen peroxide went too fast to collect oxygen at a measurable rate. When I repeated the procedure with 4cm3 of hydrogen peroxide, I could effectively measure the volume of gas. I also had to change the gas syringe because at first the reaction did not occur because a large volume of gas was leaking from a tear in the tube.

I also had to repeat the whole of the section with 70% concentration of hydrogen peroxide because the results were all anomalous when compared to the rest of the data. I will talk about why this might have been in my evaluation.

Another factor which I found out later when I drew my graphs was that there were limitations to the range of results I collected, so I decided to collect more results. I have explained this later on.

Results

Below is a table of the results I collected, including all the results which I had to repeat. The raw results can be seen in the appendix.

Figure 4. Full table of results.

Figure 4. Full table of results.

Because my results were mostly concordant, or at the very least there was only a 2cm3 difference between any 2 repeats out of 3, I decided that I did not need to repeat any of the procedures (apart from the whole of concentration 70%, which I will discuss later). This enabled me to work out an average by adding up three repeat values and dividing by 3. For example, the 100% concentration average would be (48+49+48) ÷ 3.

Below is a table showing the average results (Fig. 5).

Figure 5: average volumes of oxygen produced for each concentration of hydrogen peroxide

Figure 5: average volumes of oxygen produced for each concentration of hydrogen peroxide

From these results, I can instantly see that less gas was evolved after the first 5 seconds as the concentration decreased and that the overall volume of gas also became successively lower in each decreased concentration. This is because there were more molecules of hydrogen peroxide in the higher concentrations, meaning more collisions took place and there was a greater probability of successful collisions. This resulted in more enzyme-substrate complexes formed in the higher concentrations, and less in each decreased concentration. This supports the Maxwell-Boltzmann distribution curve I referenced earlier.

I have drawn a graph based on these average results with a curve of best fit for each concentration that will allow me to identify any anomalies.

Draw a curve of best fit on your graph.

Analysis

From the graph, I can see that as the concentration of hydrogen peroxide decreased, the volume of oxygen produced decreased as a direct result. This is because as the concentration decreased, the number of molecules of hydrogen peroxide also decreased. This decreased the number of particles that could react with each other, and so the number of collisions that reached the activation energy also decreased. This meant that there were also less successful collisions, and so less enzyme-substrate complexes formed.

The final volume of oxygen produced also decreased as the concentration decreased. This is because fewer overall collisions took place, and so a reduced number of collisions reached the activation energy. In other words, since there were fewer molecules initially, this resulted in a lower probability that the molecules would collide. This meant that there were fewer successful collisions overall (see Fig. 6 below).

The initial rate of reaction was fastest for the 100% concentration of hydrogen peroxide and gradually decreased with each successive concentration (90%, 80%, etc.). This can be explained by the collision theory, which states that the time it takes for a reaction to occur—and a set volume of gas to be evolved—is shorter for higher concentrations of substrate. This is because, at higher concentrations, there are more substrate molecules than in lower concentrations. Subsequently, if there are more molecules, then there will be more collisions taking place, and therefore more reactions between enzyme and substrate molecules per second, and so oxygen is evolved more rapidly. So, at the 100% concentration of hydrogen peroxide, the oxygen was given off more rapidly because there were more substrate and enzyme molecule reactions.

From the curves of best fit, I can also see that there were no anomalous results, only some results which were slightly above or below the curve, though they were not excessively distorted. This shows that my results were relatively accurate for each individual concentration.

To find out if the concentrations were accurate as a whole, I worked out the rate of reaction. This enabled me to find out if each concentration, based on the number of molecules of the substrate in each decrease of 10%, was similar or showed a pattern which I failed to identify with my previous results. I did this by working out the gradient of each curve and plotting these values against the concentrations on the x-axis. The method which I used to do this can be seen below. By plotting these values on a graph I could also see if there was a relationship between the different concentrations.

Figure 6: average final volumes of oxygen for each concentration of hydrogen peroxide

Concentration of Hydrogen Peroxide100%90%80%70%60%50%

Final Volume of Oxygen (in cm cubed)

88.3

73.3

63.7

63.7

44.7

37

Evaluation

Overall, I believe my experiment went well and that I gained sufficient results because I repeated each concentration three times and investigated eight concentrations in total. I believe that my results were also relatively reliable because as the concentration decreased the volume of oxygen produced also decreased. For example, the 100% concentration of hydrogen peroxide evolved a final average volume of gas of 77cm3 of oxygen while the 90% concentration evolved a final average volume of 73.3cm3. Also, most of the points were on or close to the curve of best fit for each concentration. However, there are some factors that I must take into consideration.

Apparatus Limitations

Firstly, there were limitations on the apparatus that I used. Each piece of apparatus has an apparatus error with an upper and lower limit. For example, the balance had an apparatus error of ±0.01 which means that since I used 0.2g of yeast, this value could either be 0.21g or 0.19g. This obviously affects the amount of catalase present, which means that there could be more or fewer collisions (and resulting successful collisions) between enzyme and substrate molecules depending on the greater or lower mass of yeast. For example, if there were more molecules of yeast, the rate of reaction would increase because there would be more collisions between enzyme and substrate molecules. This would result in a greater probability of successful collisions, and therefore more enzyme-substrate complexes being produced. This means that in my results, the volume of gas produced in the first 5 seconds may have been higher than it should have been if I had used exactly 0.2g of yeast. This could have been a reason for the very fast rate of reaction of the 100% hydrogen peroxide, which showed up as an anomalous result on my first rate of reaction graph.

The same idea applies to the substrate concentration in that the pipettes also had an apparatus error. This means the amount of substrate could have been different for each repeat, even though I used the same concentration. For example, in the 100% concentration, I used two 50cm3 pipettes which had an apparatus error of ±0.01. So in 100cm3, the actual volume could have been either 99.98cm3 of hydrogen peroxide or 100.02cm3of hydrogen peroxide, meaning more or fewer molecules of hydrogen peroxide. If there were fewer molecules of hydrogen peroxide, there would have been fewer collisions between molecules of enzyme and substrate, resulting in fewer enzyme-substrate complexes being made.

However, I do not believe the substrate concentrations were significantly different because my repeats were mostly concordant, so a similar amount of oxygen was produced which must mean that there was a similar number of substrate molecules in each concentration. For example, three repeats with the 100% concentrated solution yielded 48cm3, 49cm3 and 48cm3 of oxygen, respectively.

Choice of Method

I tried to select the method I considered would be most accurate. I decided on the gas syringe method because, as I explained in my section on preliminary work, it measured the volume of gas directly and minimised the volume of oxygen which could potentially dissolve in water. However, some oxygen was displaced in the gas syringe and I had to solve this by subtracting this small amount from the volumes produced in each of the reactions.

Also, I noticed if the barrel was wet, the syringe often got stuck for a short time before it recorded the volumes of gas. To prevent this I had to dry out the barrel and syringe before commencing the procedure. It was very hard to insert the small 5cm3 beaker into the conical flask, and when it came to tipping it over, some of the substrate was still trapped inside the beaker. I solved this by swirling the conical flask constantly throughout the reactions, which seemed to solve the problem, although this meant that the amount of swirling had to be the same in order to ensure a fair test. I tried to keep this constant by making sure I swirled the conical flask evenly.

The accuracy of the results showed that this factor did not distort the results too much, and so a similar amount of substrate molecules were present in each reaction. For example, three repeats with the 80% concentration had values of 32cm3, 33cm3, and 32cm3, respectively, which means that a similar number of substrates was present in each reaction.

Another factor which was hard to measure was the volume of gas produced, because some of the higher concentration reactions were very fast, so it was hard to read the correct values every time. I tried to make this as accurate as possible by keeping my eyes level with the gas syringe. Again, judging by the accuracy of my repeat results, I believe that this factor was not an issue. Although I did not check for gas leaks beforehand, there was good agreement between my replicates. In the 60% concentration, the repeats at 5 seconds were 20cm3, 21cm3 and 20cm3, which is concordant.If my replicates had not been so close I would have had to change the tube.

Surface Area of Yeast Molecules

I ground up the yeast to try to make the surface area as similar as possible because the surface area is a major factor in my experiment. A larger surface area means there are more molecules being exposed to collisions with other molecules, with sufficient energy to cause a reaction. This means that having the same surface area of yeast in each reaction is very important in ensuring a fair test because the number of molecules exposed to collisions must be the same.

Consistent Temperature

Temperature is a major factor which affects the rate of reaction. This is because, at higher temperatures, molecules of both enzyme and substrate have more kinetic energy and collide more often. This results in a bigger proportion of molecules having kinetic energy greater than that of the activation energy. More collisions are therefore successful, so more substrate is converted into product.

The reaction is exothermic, meaning heat is produced in the reaction. The higher the concentration, the more heat will be produced. This is because the molecules of both substrate and enzyme have more energy, therefore they collide more often and produce more heat energy. This heat energy is transferred to the environment.

Although I tried to control the temperature in a water bath, and to good effect (a constant external temperature was produced and the heat energy was dissipated), I could not control the amount of heat given off in each reaction. This could have affected my results for several reasons. Firstly, more oxygen dissolves in water at low temperatures than at high temperatures, meaning that for the reactions involving low concentrations, more oxygen would have dissolved than in the higher concentrations because of the decreased amount of heat energy given off.

Because the volume of oxygen dissolved in the reaction is not constant for all reactions, and less oxygen is dissolved in water at higher temperatures, this would have affected my results. This may have been why the difference in the final volume of oxygen produced was not equal, but instead decreased in steps of 3.7cm3, 9.6cm3, 14.4cm3, 4.6cm3, and 7.7cm3.

Concentration of Hydrogen Peroxide

The different concentrations of hydrogen peroxide that I made could not have been exactly accurate because this would have meant that the volume of gas evolved would have increased in equal steps, which it did not. For example, the final average volumes of gas were as follows: 77cm3 for 100% hydrogen peroxide concentration, 73.3cm3 for 90%, 63.7cm3 for 80%, 49.3cm3 for 70%, 44.7cm3 for 60% and 37cm3 for 50%. As I have mentioned earlier, this decreases in steps of 3.7cm3, 9.6cm3, 14.4cm3, 4.6cm3, and 7.7cm3, which is far from equal.

This may have been because I only used a pipette when measuring the hydrogen peroxide, and poured the water into the volumetric flask to make up the rest of the 100cm3. I believed this was accurate, but upon reflection, using a pipette would have been much more accurate as pipettes have a much lower apparatus error than volumetric flasks. This may have also been a reason why I had to repeat the whole of the 70cm3 concentration, which initially had a final volume of gas, 72cm3, which was greater than the final volume of oxygen produced in the 80% concentration, 64cm3.

Clean and Dry Equipment

I also had to make sure I washed out the conical flask and beaker thoroughly with distilled water and dried them sufficiently. If I hadn’t, I could have risked further diluting the solutions. This would have affected the number of molecules of hydrogen peroxide present, which in turn would have affected the number of collisions between enzyme and substrate molecules. For example, if there was still 1cm3 of water remaining in the conical flask and beaker combined, then an 80% concentration of hydrogen peroxide would be closer to 79%. This can be shown by the simple calculation of (80 ÷ 101) x 100 = 79.2%.

Conclusion

Overall I believe that my data reflects my hypothesis that “as the concentration of hydrogen peroxide decreases that rate of reaction will decrease consequently because there will be few collisions between enzyme and substrate molecules due to a decreased number of molecules”. This is demonstrated by my rate of reaction graph, which shows that for the 100% concentration of hydrogen peroxide, the rate of reaction was 8cm3 second-1, and the 90% concentration was only 7.4cm3 second-1.

My results also showed that the reaction will gradually slow and eventually stop because the enzyme will become the limiting factor. This is shown when oxygen stops being produced and the same results are recorded five times. For example, I knew that the 100% concentration of hydrogen peroxide reaction was over because I recorded 88cm3 at least five times.

However, I also believed that if I halved the concentration then the rate of reaction (volume of oxygen produced) would also be halved, and so the rate would be proportional to the concentration. This would show that the reaction is a first-order reaction. Though in theory, this should be the trend, my results did not demonstrate this pattern.

So, although my results did show a positive correlation, it wasn't necessarily an accurate correlation because my results do not follow specific trends. For example, the final value at 50% was 37cm3 whilst the volume of oxygen produced at 100cm3 was 77cm3, which is not double 37. Again, the final volume of oxygen produced at 30% was 27.3cm3, whilst the final value produced in the 60% concentration was 44.7cm3, which is also not double.

Line of Best Fit

As can be seen from the rate of reaction graph, the concentrations of 50%, 60%, 70%, 80% and 90% are relatively even and would suggest that I have drawn the line of best fit in the correct location. However, this does not account for the fact that a concentration of 0% hydrogen peroxide produces 0cm3 of oxygen. If the line of best fit is correct, it would make this value an anomaly, which clearly it is not since it is the most accurate value on the graph.

The line of best fit that crosses through (0,0) therefore makes much more sense, and also shows that the concentrations of 50%, 60%, 70%, 80% and 90% are still quite even. However, this presents a problem because this either suggests that the concentration of 100% is not accurate and is an anomaly, or that the line of best fit should actually be a curve of best fit.

This presents me with new limitations because I did not test any of the concentrations below 50%, which would clearly define whether the graph should have a line or a curve of best fit.

Further Experiments

Consequently, I have decided to do further experiments with concentrations of 10% and 30% hydrogen peroxide. I will use exactly the same method as I did previously, and since I still have some yeast left, I can still use the same batch of yeast. I will then work out the gradient of the two concentrations and plot them on a rate of reaction graph along with the other concentrations. Since it had a rate of reaction that was so much higher than the other values, I will also repeat the 100% concentration of hydrogen peroxide because I believe this was an anomalous result.

Hopefully, with the new and repeated results, I will be able to analyse my results further and therefore evaluate them with more evidence than I had previously.

Below are two tables of results showing my repeated experiment with a concentration of 100% and the two new concentrations of 10% and 30% hydrogen peroxide (Fig. 7).

Figure 7: repeated experiment with a concentration of 100% and with two new concentrations of 10% and 30% hydrogen peroxide

Figure 7: repeated experiment with a concentration of 100% and with two new concentrations of 10% and 30% hydrogen peroxide

I will work out the gradient of these new results and plot them on a new rate of reaction graph. This should tell me whether the reaction is indeed a first-order reaction, or if a curve of best fit is required.

Draw a new graph.

Now that I have carried out the repeats and plotted the points on the rate of reaction graph, I can see that the graph is in fact clearly linear. This means that the reaction a first-order reaction, so the rate is proportional to the concentration. I believe that the data also shows a strong positive correlation, and there are few outliers, which shows that my results are accurate.

I have drawn a line of best fit to clearly illustrate this trend. The line of best fit also suggests values of concentrations which I have not investigated. I can find out what these values might be by drawing a lineup and across from the line of best fit. So, for example, the 40% concentration should have a curve gradient near to the value of 3.

Overall, there is a pattern showing a constant trend in that as the concentration decreases the rate of reaction decreases too, and the overall volume of gas evolved also decreases. This is because at higher concentrations there are more molecules of substrate, so more collisions take place, resulting in more enzyme-substrate complexes being formed.

This is shown in the table with all the results I have gained (Fig. 8).

Figure 8: full table of results, including 10% and 30% concentrations of hydrogen peroxide.

Figure 8: full table of results, including 10% and 30% concentrations of hydrogen peroxide.

Apparatus Error

Apparatus error was one of the main factors in my experiment which I tried to keep at a minimum. I did this by only using pipettes, which have a very small apparatus error when compared to beakers. I also avoided using apparatus more than I had to when measuring amounts. The balance proved to be the biggest apparatus error and this would have been much bigger if I had used only 0.1g rather than 0.2g of yeast.

Below is a summary of all the percentage errors.

Scales ± 0.01

50cm3 pipette ± 0.01

20cm3 pipette ± 0.03

10cm3 pipette ± 0.02

Balance (0.01 ÷ 0.2) x 100 = 5%

Concentrations

  • 100% using 2 x 50cm3 pipettes: (0.01 ÷ 50) x 100 = 0.02% x 2 = 0.04%
  • 90% using 1 x 50cm3 pipette and 2 x 20cm3 pipettes: (0.01 ÷ 50) x 100 + ((0.03 ÷ 20) x 100) x 2 = 0.32%
  • 80% using 1 x 50cm3 pipette, 1 x 20cm3 pipette and 1 x 10cm3 pipette: (0.01 ÷ 50) x 100 + (0.03 ÷ 20) x 100 + (0.02 ÷ 10) x 100 = 0.27%
  • 70% using 1 x 50cm3 pipette and 1 x 20cm3 pipette: (0.01 ÷ 50) x 100 + (0.03 ÷ 20) x 100 = 0.17%
  • 60% using 1 x 50cm3 pipette and 1 x 10cm3 pipette: (0.01 ÷ 50) x 100 + (0.02 ÷ 10) x 100 = 0.04%
  • 50% using 1 x 50cm3 pipette: (0.01 ÷ 50) x 100 = 0.02%

Total apparatus error for apparatus used for concentrations = 0.86%

Total error for apparatus: 5 +0.86 = 5.86%

Considering the whole experiment, 5.86% is a relatively small apparatus error. Taking into account that the balance contributed to 5% of this error, the remaining error is minimal.

kerrie watret on January 30, 2020:

outstanding piece of biology! my hat goes off to you bud

oli sykes on May 01, 2019:

great job

M on March 20, 2019:

Excellence piece of work! Top job

Agash Praba on June 19, 2014:

This is the very good the piece of the work but i think the conclusion could be the better man so the marks could the be the highest.

tanks.

biochemi on January 19, 2014:

Nice hub with great information about enzyme kinetics.

Quizitive on April 09, 2013:

(Ignore the last question)

What board gave the grade?

Quizitive on April 09, 2013:

What mark did this get?

Alevelz on May 01, 2012:

Thanks, this is great! full marks..nice!

How does the concentration of hydrogen peroxide affect catalase?

If the buffering is insufficient, the catalase reaction decreases with increasing hydrogen peroxide concentration and, furthermore, with greater concentration of peroxide the proportionality between enzyme and oxygen set free also tends to become less general.

How does the concentration of catalase affect the rate of reaction?

If the substrate concentration is increased then the rate of a catalase reaction will also increase until it reaches the optimal concentration or saturation point and will remain constant. This is because there will be more substrate molecules in a higher concentration therefore a higher frequency of collisions.

How the concentration of hydrogen peroxide affects the rate of peroxide breakdown by catalase?

Once you add more hydrogen peroxide to the solution, the reaction rate will increase as more substrate molecules can collide with the enzyme, forming more product.

What is the effect of changing the concentration of the catalase?

As the concentration increased there were more and more opportunities for the hydrogen peroxide to bind the active sites of the catalase and react with a lower activation energy.