Which of the following conditions will cause ventilation perfusion V Q mismatch?

Ventilation perfusion mismatch or V/Q defects are defects in the total lung ventilation/perfusion ratio (V/Q ratio). It is a condition in which one or more areas of the lung receive oxygen but no blood flow, or they receive blood flow but no oxygen. In a healthy lung, the rate of alveolar ventilation to the rate of pulmonary blood flow is roughly equal; more precisely, because normal lungs are not perfectly matched, the V/Q ratio of a healthy lung is approximately 0.8.[1][page needed]

Pathogenesis[edit]

Consider some scenarios where there is a defect in ventilation and/ or perfusion of the lungs.

In a condition such as pulmonary embolism, the pulmonary blood flow is affected, thus the ventilation of the lung is adequate, however there is a perfusion defect. Gas exchange thus becomes highly inefficient leading to hypoxemia, as measured by arterial oxygenation. A ventilation perfusion scan or lung scintigraphy shows some areas of lungs being ventilated but not adequately perfused. This results in a raised Alveolar-arterial (A-a) gradient which is not responsive to supplemental oxygen.

In conditions with right to left shunts, there are also ventilation perfusion defects with high A-a gradients. However, the raised A-a gradients in these cases are responsive to oxygen therapy. In cases of right to left shunts more of deoxygenated blood mixes with oxygenated blood from the lungs and thus to a small extent the condition might neutralize the high A-a gradient with pure oxygen therapy. Patient with parenchymal lung diseases will have an increased A-a gradient with moderate response to oxygen therapy.

A patient with hypoventilation will have complete response to 100% oxygen therapy.

Diagnosis[edit]

To check whether we are suffering from ventilation perfusion mismatch or not, we need to get a lung scan. It is a simple test to check ventilation and perfusion separately. If both scans are done simultaneously then it is called as V/Q scan. Ventilation Scan is done first as it is easy to wash out tracer gas from lungs with the help of hyperventilation than clearing the tracer radioactive material from blood.

Indication: It is most commonly done in suspected case of pulmonary embolism.

  1. Ventilation Scan: Takes 15 to 20 minutes. A radioactive tracer gas is inhaled and then this radioactive tracer gas is traced (looked) by taking pictures from specialised camera which capture the route and location of tracer gas. These pictures show us the part of lung devoid of tracer gas and then we correlate it with different types of lung pathology.
    • By using a mouth piece while closing nose with the help of clip, person is asked to inhale the radioactive tracer gas for few minutes and pictures are taken at regular intervals.
    • Then person is asked to hold the breath and remain still for at least 10 seconds and final picture is taken.
    • Then by looking upon the picture, the poorly ventilated or overvented area is noted.
  2. Perfusion scan: It is done by injecting a radioactive tracer into a peripheral vein usually in arms and then following the path of tracer by camera as the tracer moves to lungs. It tells us about the area of lung poorly perfused or any type of obstruction to the flow like in case of pulmonary embolism which will seen on image as an area devoid of tracer element distal to the obstruction.

Results:

  1. Ventilation Scan is abnormal but perfusion scan is normal indicating abnormal airway suggesting COPD or ASTHMA.
  2. Ventilation Scan is normal but perfusion is abnormal indicating any obstruction to the blood flow (perfusion), may be because of the PULMONARY EMBOLISM obstructing the flow.
  3. Both scans are abnormal. It may be found in PNEUMONIA or COPD.

Results are reported in following way:

  1. Normal - No abnormality found.
  2. Low Probability - Chances of blood clot is low. Needs further and more testing.
  3. Intermediate Probability - Scan shows possibility of blood clot. Needs more testing.
  4. High Probability - High chances of clot. Needs treatment.

Management[edit]

Through ventilation and perfusion scans, the abnormal area of lung may be localized. A provisional diagnosis of COPD, asthma or pulmonary embolisms may be made. Treatment of these underlying conditions may address ventilation perfusion mismatch.[citation needed]

Management of the condition may vary. If ventilation is abnormal or low, increasing the tidal volume or the rate may result in the poorly ventilated area receiving an adequate amount of air, which ultimately leads to an improved V/Q ratio.[citation needed] Conversely, if perfusion scan is of low quality showing low perfusion to lung as in case of hypovolemia, treatment of the conditions is by giving it fluid and using inotropes in case of shock.[citation needed]

References[edit]

  1. ^ Costanzo, Linda (2014). Physiology (5 ed.). Philadelphia, PA, USA. ISBN 978-1-4557-0847-5.

What causes high VQ mismatch?

An increased V/Q mismatch is caused by a decrease in blood flow to the lung, for example a pulmonary embolism. A decreased V/Q mismatch is caused by a decrease in ventilation or an airway obstruction, for example Asthma. A V/Q mismatch due to a perfusion defect will improve with 100% oxygen therapy.

What does the ventilation perfusion v q represent?

For effective gas exchange to occur, alveoli must be ventilated and perfused. Ventilation (V) refers to the flow of air into and out of the alveoli, while perfusion (Q) refers to the flow of blood to alveolar capillaries.

Which of the following diseases will result in a high ventilation perfusion V Q mismatch quizlet?

Which of the following diseases will result in a ventilation/perfusion (V/Q) mismatch? All of the above: Asthma, pulmonary edema, & emphysema: All three pulmonary diseases result in V/Q mismatches due to decreased ventilation and/or impaired diffusion of gases at the alveolar/capillary membrane.

Does hypoventilation cause VQ mismatch?

Shunt and low V′A/Q′ regions are two examples of V′A/Q′ mismatch and are the most frequent causes of hypoxaemia. Diffusion limitation, hypoventilation and low inspired PO2 cause hypoxaemia, even in the absence of V′A/Q′ mismatch.